• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Recent content by levien

  1. Printhead Problem on VP540

    I had the same problem,, Changed heads: same problem Changed cables to other head(cross wired): problem moved to the other head, so head board. Changed the head print: problem gone ! regards Levien de Nooijer LA service, Terneuzen
  2. Test pattern weird after change heads and fuse on XC540

    Problem solved Problem with the black stripes is solved: new main head board ! Thank you all for reply's regards Levien:signs101:
  3. Test pattern weird after change heads and fuse on XC540

    In our case , it doen't matter what we print....the wide bands of spraying continous black ink of one side of the black head still appears after we send , no matter what, to the printer. In the picture you see this happening after sending a test pattern.
  4. Test pattern weird after change heads and fuse on XC540

    yep... I did...plzzz...i know. New heads allready ordered.... But same issue with continously printing of one side of black head still remains. Allready changed transistors (on cooling plate). Changed also the 2 D/A converter chips....no change... Pfff...keep you posted....
  5. Test pattern weird after change heads and fuse on XC540

    update... Just replaced the print carriage board for somewhat different layout but same connectors. Blew instantly middel fuse + transistors of black head. Placed back old board...replaced defect transistors. Testing: They print only just the half of each head. (exept one head which is ok)...
  6. Test pattern weird after change heads and fuse on XC540

    Still same problem Have schematic now so that is much easier. Color board? The heads are attached with flat cables to a print carriage board and from their with long flat cables to the head board. I replaced the short flat cables but no change. I replaced the transistors on the main head board...
  7. After blowing fuse black/yellow, half black is firing continuous

    I have changed the heads but blown a (black/yellow) fuse,...forgot the power.... after replacing fuse: Test print gives large black stripes from begin to end from 1 side of the black head. It begins when the testpattern is starting to print and then the half part of the black printhead keep on...
  8. Service manual for XC 540 ?

    Service manual.... got it...thanks
  9. Test pattern weird after change heads and fuse on XC540

    Somebody knows what do to? After replacing 3 heads, a fuse (black/yellow) was blown...yeah...i know... forgot the power switch. Replaced the fuse and yellow came back alright, but black gives stripes like it continous with spraying after it begins..... When I print more left on the media the...
  10. Service manual for XC 540 ?

    Service manual.... Hi there, i would like a copy of this manual too(XC-540), if it is possible... i will be very grateful!! I have changed the heads but blown a (black/yellow) fuse, after replacing: Now i am getting large stripes from begin to end on 1 side of the black head. Like its spraying...