• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    ***deleted to add into previous post
  2. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    A little update after a visit from a tech... A print head wasnt needed at this time. After a ~$700 visit later this is what I was told I needed to do: 1) Set print speed to 800mm/s (SLOW as heck on an already slow printer) 2) Set to true color 3 in the quality settings 3) I was told this is a...
  3. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    Thanks for your time all! Nothing in the shop has changed. It's pretty dry here in Southern California so I don't think it's humidity. Attached is the test print. Im currently using the generic vinyl 1 default profile and I also tried the 3M and Arlon profiles that match the media I tested on...
  4. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    Oh forgot to mention, on the 3M and Arlon tests, I used the provided print profiles provided by Roland profile center website to match brand/media models. For my generic vinyl, I normally use the default generic vinyl profile. This started happening about a couple weeks ago and we typically use...
  5. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    Yes im running original TR2 inks and CL. The heater is normally at 40C which tried setting it to the max 45C and also as low as 35C just to see if its a temperature issue. On a test print of solid colors, only the more red hues have this issue. Even on a busy abstract art print, only the reds...
  6. SG-540 on TR2 Inks - Blotchy Reds/Magenta

    Hi All, I'm having some issues with printing solid red colors (see screenshot) and noticing that the default white 0.01" thick line between the each print is blurred on the vertical path (horizontal is sharp). I've done the following while trying to troubleshoot: Calibration Bi-directional...
Top