• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. Roland Truevis VG2-640 - Banding issues

    Yes, head replacement solved the issues.
  2. Roland Truevis VG2-640 - Banding issues

    Besides: It seems easy to replace the head including cap and damper your self? https://www.digiprint-supplies.com/en/vg-i-assy-inkjet-head-250l-6000006702 I looked at a YouTube video which seems relatively easy.... Any thoughts?
  3. Roland Truevis VG2-640 - Banding issues

    Thx for the tip, will try this before asking for replacement.
  4. Roland Truevis VG2-640 - Banding issues

    Thx every one for all tips. Also nozzle mask is not helping 100% out. Desided to ask for a head replacement.
  5. Roland Truevis VG2-640 - Banding issues

    thx for your quick reply. I tested this immediately. Uni directional is slightly better but not acceptable. (files attached) I'm out of options I guess.... besides calling for support and change the print head :-(
  6. Roland Truevis VG2-640 - Banding issues

    Just tested and indeed it seems only Cyan. See attachments.
  7. Roland Truevis VG2-640 - Banding issues

    Found and cleande the Encoder strip, no changes. Horizontal banding still the same. Some more examples attached. Anyone.....?
  8. Roland Truevis VG2-640 - Banding issues

    I will try cleaning the encoder strip. Where to find it? Do I need to remove anything for this. Default temp is set to 40 degrees celcius for the printbed and 45 for the last one.
  9. Roland Truevis VG2-640 - Banding issues

    UPDATE: changed the feed calibration to -0.5 and even -1.0 Totally no difference in output :-(
  10. Roland Truevis VG2-640 - Banding issues

    wes70 heat settings up or low? I have no clue
  11. Roland Truevis VG2-640 - Banding issues

    thx, will try!
  12. Roland Truevis VG2-640 - Banding issues

    Hi, were having issues with banding on our Roland VG2. Problem exists in all solid colors and on different media types See attachments: - example - gap adjustment checked - calibration checked - nozzle test checked What else can we do to resolve this? Any thoughts? Thx in advance regards, Jovan
  13. Need Help no ink flow after replacing dampers - roland vs540i

    update: we gave up and bought a new printer. thx for all the tips!
  14. Need Help no ink flow after replacing dampers - roland vs540i

    Hi, thx. there as a bit air in it. Removed it with a syring. Dampers are full too now. Unfortunately still the same issue. No ink is flowing. Any ideas?
  15. Need Help no ink flow after replacing dampers - roland vs540i

    We managed to replace the dampers and cap top. Problem now is that the ink is, for some reason, not flowing anymore. - powerful cleaning, no ink flow - choke cl, no ink flow - fill ink, no ink flow what could be the cause of this? Can someone help me out?
  16. Need Help Looking for a Roland SV-540i service manual

    Sorry, typo: VS-540i Can you help me out?
  17. Need Help Looking for a Roland SV-540i service manual

    Can someone help me out with a Roland SV-540i Service manual? many thx in advance.
  18. Need Help VS-540i banding issue

    Hi, our VS540i is having banding issues. Weird enough the banding only starts after approx. 10cm of printing. (the first 10cm are still perfect) Already tried this without any result: - print head cleaning - print head soaking - replace feed pinch rollers - calibration - change print temperature...