• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. Transistor for Roland

    I would need to know exactly which model you have to advise you. It would involve hooking the suspected head up to a different channel on the printer. You are now entering an area that should really be dealt with by an experienced technician on-site. I don't know your level of technical...
  2. Where can I buy an alignment scope?

    The LED's in the Celestron's lighting have enough of a blue content to make it very easy to see yellow, so no need to do anything but look at the screen. Hey Trent - staying busy in the warm where 50 degrees is like a blizzard for us.
  3. Transistor for Roland

    If you are checking it because you are blowing fuses, then you do not need to remove it from the board, as it is shorted and will read zero ohms across 2 legs, even while still in the board. If you are checking it for any other reason, you will nedd to remove it from the circuit to get an...
  4. Where can I buy an alignment scope?

    I'm the tech tbaker (Hey Trent!) mentioned as having the Celestron digital microscope. It works very well for me, especially as I use a netbook in the field. It makes doing the fine alignment on the Mimaki very easy. One of the useful features for me is its ability to take pictures and videos...
  5. Wall decal edges curling

    Also, as the cutter blade is cutting through the vinyl and ink, this may allow the ink to leach around the edge of the cut and down to the adhesive, also attacking and degrading the adhesive at the edge of the cut. iSign's explanation probably has the most dramatic impact.
  6. convert back to ecosol max from mega ink

    Agree with Bobby. I worked for MegaInk for 2 1/2 years as a tech and color profiling specialist. Bobby's instructions are spot on the way we did it.
  7. J

    Martin, Sorry, I've been out of town. I'll stop by on Monday afternoon. I'll also call you...

    Martin, Sorry, I've been out of town. I'll stop by on Monday afternoon. I'll also call you Monday AM. My number - 561-441-6658 Regards, Jim
  8. WHERE DID MY BLACK GO PrismJetXtra

    Check your PM...
  9. SP300V not feeding straight.

    Also, the pinch rollers may be getting worn flat. The outer pinch rollers are angled to push the media outward on the edges. The older printers are starting to have this sort of problem as the rollers flatten out from wear. I have replaced the rollers on a number of older Rolands recently, and...
  10. Banding

    When cleaning the encoder strip, use alcohol with a low water content or pure alcohol, which is better. I had a customer use 70% alcohol and he wiped out his encoder strip. It is a piece of graphics film and water will soften the emulsion and make it easy to damage during cleaning. If you've...
  11. Looking for Help Falcon 2 "Head Overcharged" 075 code...

    Did you enter the print head "head rank" when you installed the head?
  12. Epson DX4 Print Heads - Are they all the same?

    I am a Tech, Roland certified on the older ProII and VersaCAMM's, though I don't work for a Roland dealer anymore... Started out back in the day repairing Radar, Communication and Navigation systems in the Navy for 6 years, fixing boards rather than replacing them. Now, I'll try my hand on any...
  13. Epson DX4 Print Heads - Are they all the same?

    The head rank setting is determined by the print head manufacturer. It is a fine tuning of the voltage setting to account for variations in the characteristics of the print head nozzles in each head. When you enter the head rank numbers in your printer, you are telling the printer what the...
  14. GRAINY PRINT USING ROLAND 545 with ecosolv inks.

    Your problem is most likely bi-directional misalignment. If you want to easily confirm this, run a print in bi-directional and again in uni-directional modes. There is a bi-directional calibration you can run in the user menu. Look in your user manual under "Making corrections for printing"...